Pocket Otoscope Replacement Head and BulbIDW5178
1517-P-1019
£80.77
£96.92 inc VAT
Keeler Pocket Replacement Head and Bulb
Replacement diagnostic head and bulb for Keeler Pocket otoscopes and ophthalmoscopes.
Pocket Otoscope Features
Full diagnostic capability in a pocket sized instrument
Closed head design particularly suited to pneumatic testing
2.5x magnifying lens removable to allow the introduction of small instruments
Genuine Halogen Illumination for clear and accurate aural images
Pocket Ophthalmoscope Features
Brilliant halogen illumination
+20 to -20D lens range for clear and effortless examination of all ocular structures
Ideal for domiciliary or ward work or as a second instrument
Apertures and Filters:
Wide Angle - Illuminates the largest area of fundus for the best possible general diagnosis through a dilated pupil.
Intermediate - Permits easier access through and undilated pupil and in peripheral examination. Particularly useful in paediatric examination.
Red Free - The red free filter is used to examine blood vessels in fine detail. By filtering out the red light, blood vessels are silhouetted against a dark green background.
Macular - Designed specifically for examination of the macular region of the fundus where a larger beam would create excessive pupillary reaction or patient discomfort.
Slit - Used primarily to determine retinal elevations and depressions but may also be used to assess anterior chamber depth.
Fixation Cross - Projects a graticule onto the retina for assessment of the degree and direction of eccentric fixation.
Replacement diagnostic head and bulb for Keeler Pocket otoscopes and ophthalmoscopes.
Pocket Otoscope Features
Full diagnostic capability in a pocket sized instrument
Closed head design particularly suited to pneumatic testing
2.5x magnifying lens removable to allow the introduction of small instruments
Genuine Halogen Illumination for clear and accurate aural images
Pocket Ophthalmoscope Features
Brilliant halogen illumination
+20 to -20D lens range for clear and effortless examination of all ocular structures
Ideal for domiciliary or ward work or as a second instrument
Apertures and Filters:
Wide Angle - Illuminates the largest area of fundus for the best possible general diagnosis through a dilated pupil.
Intermediate - Permits easier access through and undilated pupil and in peripheral examination. Particularly useful in paediatric examination.
Red Free - The red free filter is used to examine blood vessels in fine detail. By filtering out the red light, blood vessels are silhouetted against a dark green background.
Macular - Designed specifically for examination of the macular region of the fundus where a larger beam would create excessive pupillary reaction or patient discomfort.
Slit - Used primarily to determine retinal elevations and depressions but may also be used to assess anterior chamber depth.
Fixation Cross - Projects a graticule onto the retina for assessment of the degree and direction of eccentric fixation.